Professional IP-Based PDU Remote Power Reboot Switch With Web Control Timer | eBay

More details

Report item - opens in a new window or tab Description current Shipping and payments eBay item number:191527413765 Seller assumes all responsibility for this listing. Last updated on  Dec 07, 2016 16:47:40 PST  View all revisions Item specifics Condition: New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. See all condition definitions- opens in a new window or tab ... Read moreabout the condition Brand: Unbranded/Generic MPN: IP-P2 UPC: Does not apply Weesolutions Visit my eBay store   Search Store Store Categories Store home Audio Video Cables/AdaptersAudio Video ExtendersVideo ProductsAudio ProductsSwitch BoxesWireless ProductsPower Controllers/AdaptersSecurity Surveillance ProductsSmart Outdoor Lighting Home AutomationPC AccessoriesAC/DC Power AdaptersElectronic GadgetsOtros Professional 2-Port Remote Power Switch - Web Control With Auto Ping Support Professional 2-Port Remote Power Switch - Web Control This premium 2-outlet power controller system is designed to provide remote and central management of AC power distribution through local network or internet.  This intelligent remote power controller integrates versatile functions including detailed scheduling for operations including remote power reboot, equipment power on/off control and so on. By building centralized administration for equipment power controls, this remote power switch helps administrators control network devices or power equipments from different locations and saves companies money as technical personnel can cover larger areas and multiple remote locations without wasting time on traveling. Other benefits from employing this intelligent power distribution system including: Reduction of server/data center downtime and labor costs with remote power control. Remote power source management. Complete power control via web, network or push buttons on the panel. Network equipment monitoring and power rebooting (autoping/power reboot). Real-time power consumption monitoring, reporting and alarming Avoids power surges and UPS overloads by controlling power-on and power-off sequences. React on all power alert events in a predefined way. Auto-reboot the failed network devices. Independent Control of Power Ports Each AC power plug can be independently powered on, off or power cycled for a immediate reboot or reboot with a timed delay and power event scheduling for network management, energy management and system security. Complete control over when and in which sequence equipment is restored. with a time delay or scheduled for On/Off shutdowns to conserve energy in the data center.  An absolute necessity to control servers, routers, network equipment and industrial machinery securely from your web browser. Eliminate service calls and increase reliability. Eliminate problems with brownouts and blackouts. Web Control Operation Its intuitive web control panel provides various important power control functions including remote power scheduling, remote power setting and remote power status report, which can all be accessed via internet or local network: Advanced Power Operation Scheduling This unit can perform power operation at any specific moment or on daily, weekly, monthly or yearly basis. For instance, users can program the connected power device to be turned on/off or rebooted performed daily at 11:00 AM, weekly on every Sunday at 7:00PM or yearly with specific month, day and time programmed in advanced. Arrange Power-Up Or Shutdown Sequence With Timed Delay Supports power cycling sequence with priority so each power outlet can be turned on/off or rebooted with timed delay in seconds or minutes to prevent all power devices from starting up simultaneously to cause sudden overloading or dropped loads. Auto Ping Setup For Reboot/Recovery Of Crashed Systems The auto-ping function will automatically check the monitored network device's IP address periodically. Once the network equipment failing to respond the ping request over the user-defined event counts and preset time period, the programmed power action will be executed, which can be a timed reboot and alert email sent. Up to 2 networked systems can be continuously monitored with auto-ping setup for automatic power control upon loss of contact. Secure User Access Control This intelligent power switch supports multiple users access with password security. Manager can assign permissions for each user to access all or only the power outlets assigned. IP/Mac Filter Protection This unit also supports firewall function by providing both IP and MAC address filters to prevent unauthorized user from gaining access to the switch and devices connected through the network. Web Control Panel Screenshots Multiple Safety Self-Protection This intelligent power switch provides 2 different system shutdowns for safety measure: Auto Shutdown By Current Overload This remote power switch has a circuit breaker built in for protection of devices connected to the power switch. This remote power switch will be automatically shut down for responding to a current overload or short circuit condition. Manual Shutdown By On/Off Power Button A master power on/off button on the switch box itself for local operator to override the remote control mode and take control of this power switch in an emergency. No need to unplug the power cord or run to trip a breaker from the power panel. Power Event Alert Notification Warning alerts can be programmed to be sent out right after critical power conditions occur so manager can take preventive measures if needed. The alert message can be generated automatically via emails, SMS text messages or SNMP trap notification according to the pre-set conditions. Supports multiple recipient's email addresses for event logs and daily report. Alerts will be sent in response to the following power events: Ping failure on the network devices Device temperature rising above the preset value Electrical short circuit and current overload Administrator can also check the operation events and warning events in the recent 7 days. The event log can be viewed directly or archived by downloading from the web page in .csv file format and saved into the hard drive. Equipment Protection / Energy Savings Protect sensitive devices or valuable equipment by keeping them powered off when not in use. This prevents hackers from detecting them at all times. Very suitable for energy related or network application by powering down equipments when not needed for power savings and to save on wear and tear or powering up environmental system such as UPS, power generator, heaters, coolers, pumps, fans, lighting, signage, network routers/hubs/switches, DSL/Cable modems, ATM's, servers, firewalls and security / surveillance system, etc. at scheduled time. IP-based PDU power distribution unit with built-in web server with 2 AC power outlets. A new way to control power supply of the remote equipments via internet without the presence of personnel. Each AC power outlet can be independently controlled for power on/ off, immediate reboot with/without timed delay, power startup sequence with assigned priority and power event scheduling. Complete power control via web, local terminal or push button on the switch. Manual power on/off button to override existing power status and gain control from local access. Supports power start sequence setting with timed delay to prevent all of connected power devices from simultaneous startup together to cause sudden overload and power surge. Easy web GUI setup for scheduling power operations performed on each individual power outlet on a daily, weekly, monthly or yearly basis. Power overload protection. Auto Ping for automatic reboot of crashed systems. Monitor and auto detect any failed network equipment and perform a timed reboot or other power control function (like turning on an indicator or siren). IP filter/mask function helps manage user privileges and prevent unauthorized access to the control menu through the network. Supports multi-users access management with secure password check. Instant email and trap notification will be generated when power events occurred according to the preset event lists. Downloadable power event logs with all performed actions and power status/connection activities recorded to server. Event warning alert function by sending out email, SMS text message or SNMP TRAP to notify authorized personnel. Supports WOL (Wake On LAN) protocol for remotely powering up computers connected to this power switch. 12-AMP circuit breaker protection to avoid power overload and protect connected devices. Designed for high voltage resistance and protection for leakage of electrical currency with 12.0 Amp total max current output. Steel frame design with sturdy metal enclosure. Reboot- Remote power reboot of any device like: Network Routers, Cable/DSL Modems, Data Center, Servers or DSU/CSU,  Kiosks,ATM Machines HVAC Generators Alert Systems/Security Surveillance/DVR System Lighting Equipments/Lamps Industrial Machinery Equipments  Power Sequencing: Control the sequence by which your power outlets and attached devices activate, helping prevent circuit overload, and ensuring that attached devices power-up in an appropriate sequence. Protection: Keep sensitive devices powered off when not in use. This prevents hackers from seeing them at all times. Saving Energy: Power down equipment when not needed for power savings and to save on wear and tear. Security Notification: Power up alert devices like sirens, lamps, speakers. Intelligent Power Management: Power up environmental system like heaters, coolers, pumps, etc. with programmed schedules. Hardware Network Interface Ethernet RJ45 port x 1 Power Outlet Plug AC Power Outlet NEMA-15R x 2 Power Protection  10 Amp circuit breaker LED Indicator On/Off Status  2 Green LEDs for 2 outlets Control Mode  1 Green LED for LAN mode  Network Features Network Protocol Supports Supports TCP/IP, UDP, SNMP, DDNS, SNTP and HTTP protocols. Web GUI control through LAN/WAN network. Supports fixed and dynamic IP address. Supports NTP (Network Time Protocol ) - synchronize the time of the power controller to the Internet web time . Supports DHCP and alternate ports for Web Access Security password identification  Operation Input Power Voltage Range  85-264V AC 47-63Hz Power Source Frequency  50 ~ 60Hz Max Rated Current Output 12.0 Amp max total for both outlets. 8.0 Amp max per each power outlet. Operating Temperature  32-140 degree F Relative Humidity  0 - 95% non-condensing Dimension   153 x 123 x 44 mm (W x D x H) Power Consumption     5W Remote power switch unit AC power cord x 1 Manual/Utility CD disk Questions and answers about this item No questions or answers have been posted about this item. Ask a question - opens in a new window or tab Seller assumes all responsibility for this listing. Shipping and handling This item will ship to Thailand, but the seller has not specified shipping options. Contact the seller- opens in a new window or tab and request a shipping method to your location. Shipping cost cannot be calculated. Please enter a valid ZIP Code. Item location: Arcadia, California, United States Shipping to: Worldwide No additional import charges at delivery! This item will be shipped through the Global Shipping Program and includes international tracking. Learn more- opens in a new window or tab Quantity: Change country: -Select- Afghanistan Albania Algeria American Samoa Andorra Angola Anguilla Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Republic Bahamas Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia Bosnia and Herzegovina Botswana Brazil British Virgin Islands Brunei Darussalam Bulgaria Burkina Faso Burundi Cambodia Cameroon Canada Cape Verde Islands Cayman Islands Central African Republic Chad Chile China Colombia Comoros Congo, Democratic Republic of the Congo, Republic of the Cook Islands Costa Rica Cote d Ivoire (Ivory Coast) Croatia, Republic of Cyprus Czech Republic Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Ethiopia Falkland Islands (Islas Malvinas) Fiji Finland France French Guiana French Polynesia Gabon Republic Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Honduras Hong Kong Hungary Iceland India Indonesia Iraq Ireland Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Korea, South Kuwait Kyrgyzstan Laos Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Luxembourg Macau Macedonia Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia Moldova Monaco Mongolia Montenegro Montserrat Morocco Mozambique Namibia Nauru Nepal Netherlands Netherlands Antilles New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norway Oman Pakistan Palau Panama Papua New Guinea Paraguay Peru Philippines Poland Portugal Puerto Rico Qatar Reunion Romania Russian Federation Rwanda Saint Helena Saint Kitts-Nevis Saint Lucia Saint Pierre and Miquelon Saint Vincent and the Grenadines San Marino Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Slovakia Slovenia Solomon Islands Somalia South Africa Spain Sri Lanka Suriname Swaziland Sweden Switzerland Taiwan Tajikistan Tanzania Thailand Togo Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States Uruguay Uzbekistan Vanuatu Vatican City State Venezuela Vietnam Virgin Islands (U.S.) Wallis and Futuna Western Sahara Western Samoa Yemen Zambia Zimbabwe There are 25 items available. Please enter a number less than or equal to 25. Select a valid country. ZIP Code: Please enter a valid ZIP Code. Please enter 5 or 9 numbers for the ZIP Code. Shipping and handling Each additional item To Service Delivery* US $48.60 US $26.00 Thailand Expedited Int'l Shipping Estimated between Thu. Dec. 15 and Mon. Dec. 26 Seller ships within 2 days after receiving cleared payment - opens in a new window or tab. * Estimated delivery dates- opens in a new window or tab include seller's handling time, origin ZIP Code, destination ZIP Code and time of acceptance and will depend on shipping service selected and receipt of cleared payment- opens in a new window or tab. Delivery times may vary, especially during peak periods. Domestic handling time Estimated sales tax Will usually ship within 2 business days of receiving cleared payment - opens in a new window or tab. Seller charges sales tax for items shipped to: CA(9.5%). Return policy After receiving the item, contact seller within Refund will be given as Return shipping 14 days Money back Buyer pays return shipping Return policy details Shipping charge is non-refundable. 10 % restocking fee for product purchased over 14 days. No refund will be issued for products purchased over 30 days. Defaced or damaged items are not eligible for refund. Customers must contact us first for return authorization number before sending the package back. Products are backed up with 6 month warranty unless otherwise specified. Items sent by regular air parcel(USPS first class mail international) do not have tracking services currently, https://tools.usps.com/go/TrackConfirmAction!input.action Payment details Payment method Preferred / Accepted   Accepted   Immediate payment required for this item Immediate payment of US $115.00 is required. Seller's payment instructions International Buyers - Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying.

More details

remote power switch,remote power manager,remote power controller,network power switch,IP power switch,Remote power controller,rack mount,IP power switch,Server reboot,internet power control,power strip,remote power management